System
• 16 hardwired zones on the
system controller
• Expandable to 96
hardwire/wireless zones
• One two-wire smoke loop
• 475+ word vocabulary annunciated
through keypad or phone
• Four words assigned per zone
• Annunciated alarm type and zone
description during activation
• Internal and external voice driver
• Two and four wire smoke detector
support with smoke reset
• 512 event memory log
• Eight area split-arming
• Supports eight addressable keypads
• Phone line supervision
• High current supervision
• True battery test
• Temporal fire tone annunciation
• Smoke verification
• Bell supervision
Local and Remote Phone Access
• Answering machine override
• Full system control including
arming and disarming
• Direct access to home
control devices
• Access to two-way voice features,
including homeowner listen-in
Programming
• Installer programming software
• Remote modem programming or
direct programming through local
phone jacks
• Keypad or remote phone
programming with full
speech confirmation
• Programming through
RS232 Interface
Listings
• UL/ANSI 985-Residential fire and
1023 Residential Security Standards
• California State Fire Marshall
Home Control
• Phone/Keypad control of up to 56
lights and appliances (ON/OFF/DIM)
• Eight chaining channels allowing
16 control activations based on
one command
• Four command sets: dimming,
all lights on, all lights off, flash
• Time of day operation
• Day of the week
programming schedules
• Event driven control of lights/relays
• Phone/Keypad control of up to 56
relays: seven low current relay
activation pins plus one relay on the
system controller, eight additional
relay outputs per each EXP-8 relay
expansion module
• Manual or fully automatic operation
• X-10 compatible
Central Station Communication
• Formats include: ADEMCO Contact
ID,3-1, 4-1, 4-2
• Failure to open/close reporting
Two-Way Alarm Verification
• Enables the central station to verify
alarm activity within a residence
• Three individually controlled
microphone channels
• Adjustable sensitivity
• Sirens muted during two-way
voice activation
• Automatic activation after
digital transmission
• Homeowner access to
two-way operation
• Paging from local or
remote telephone
• Listen-in from local or remote phone
Power Specifications
• Watchdog circuitry insures integrity
of microprocessor
• AMP power supply (2 AMPS auxiliary)
ORDERING
DESTINY
®
6100 Control Panel
6160AP Keypad
RK 36 Keypad
Apex 6100
CONTROL PANEL
SPECIFICATIONS
Honeywell Security & Custom Electronics
Honeywell International Inc.
PO Box 9035
Syosset, NY 11791
www.honeywell.com
L/6100/D
January 2007
© 2007 Honeywell International Inc.