APEX — Installation and Service Manual 63
Specifications
Environmental
0° to +35° C
10 to 90%, Non-condensing
Physical
Chassis: 19.25 inches (11 RU) high x 19 in. wide x 11 in. deep
(489 x 483 x 279 mm)
Weight: 63 lbs. (29 kg) fully stuffed
Alarm
The alarm connector is a BNC type and meets SMPTE 269M-1999.
AC Power Input
Mains connection: IEC connector, separate mains input for each power
supply module
Voltage range: 100 to 240 V, 50-60 Hz, universal, auto-ranging
Inrush current for 75 Ohm system: 10.2A
Inrush current for 110 Ohm system: 9.4A
Total power: 163 Watts
APEX Plus
Total Power: Input frame 130 W, Output frame 205 W.
Fuses: 2.25 A required for 110-120 V operation. 1.6 A required for 220-240 V
operation.
Fiber Extenders
Fiber Extenders are used to connect a Remote chassis or system to a Local
chassis. In general, you need one Fiber extender per individual or group of
remote Apex chassis.
APX-FBR-EXT
Apex Fiber Extender. For use with Standard Apex chassis located more
than four meters away from local chassis. Order one pair for each remote
chassis. See
Fiber Extenders (Standard Apex Only).